At our centrally located CWB welder testing facility you will find:
  • Ten booths set up with individual fume extractors and welding stands, and five inch angle grinder with wire wheel.
  • New inverter type welding machines that can be set up with a variety of consumables for a range of procedures SMAW, FCAW, GMAW, dual shield or flux core.
  • Machining equipment for preparation and testing of welding coupons.
  • Experienced staff supervisors available to assist.
  • Free parking.

Procedure for Booking your CWB Welder Test


Please have the following information ready when booking:
  • First name, middle initial, last name
  • Mailing address (where the test report will be sent)
  • Contact phone number
  • Who is paying? Welder or Company
  • Which process is welder testing for: SMAW (stick) – FCAW (flux/wire) – GMAW (mig)
Positions CWB welder testing for:
  • Full test—doing all 4 positions
  • Check test—position depends on original ticket positions
  • Re-test—specify position
  • Flat
  • Horizontal

Test Procedure


CONTACT INFO: Steve Reid or Sheila McCrea

Phone: 604-526-2404 toll free 1-800-562-2404 or Fill out Form


Be prepared to present welding certification cards to CWB inspector.

Personal protection equipment required (P.P.E.) e.g.

- CSA approved steel toe work boots
- personal eye protection
- wear 100% cotton or wool or fire retardant material
- welding jacket or sleeves
- welding gloves

CWB Plate Test
  • 45 minutes per plate – 5/16 maximum leg length
  • 1/8” maximum build up – 1/32” maximum undercut
  • Use run off tabs – wire wheel on grinder allowed
  • No defacing of stamped area – stops and starts must be observed
  • Electrode sizes 3/32”, 1/8”, 5/32” usage – no using any grinders or files for metal removal

Guidelines for passing CWB Welder Test


  • No chipping hammer marks or stray arcs on plate.
  • Fill in the craters at the end of the grove weld.
  • Do not build weld up more than 3mm (1/8”) above the surface of the plate.
  • No grinder, saw blades, files or tools for metal removal are allowed.
  • Ensure that you do not weave up against the square cut plate, always point to the square cut plate when welding to it.
  • You are required to make stop/starts as directed by the CWB representative. Ensue that stop/starts are welded correctly.
Stop/start technique

Using SMAW, restart the arc ahead of the crater, move back to the crater, fill it and continue to weld.

  • Using FCAW, restart in the centre of the weld crater.
  • The second pass must touch the beveled plate.
  • Technique for the fill passes is up to the welder, but it is generally considered easier with less chance of leaving a defect in the weld if stringer passes are used. The vertical position may be an exception.
  • The legs of the fillet weld must not vary in size by more than 1.5mm (1/16”).
  • Fillets size weld is 8mm (5/16”) maximum (this means that you can put on a 5mm (3/16”), 6mm (1/4”) or 8mm (5/16”) fillet weld).
  • If attempting three passes in the root area, make sure enough room is left to fuse the third pass to the backup strip.